The caesium standard is a primary frequency standard in which electronic transitions between the two hyperfine ground states of caesium-133 atoms are used to control the output frequency. The first caesium clock was built by Louis Essen in 1955 at the National Physical Laboratory in the UK. and promoted worldwide by Gernot M. R. Winkler of the USNO.
Caesium atomic clocks are the most accurate time and frequency standards, and serve as the primary standard for the definition of the second in the International System of Units (SI) (the metric system). By definition, radiation produced by the transition between the two hyperfine ground states of caesium (in the absence of external influences such as the Earth's magnetic field) has a frequency of exactly 9,192,631,770 Hz. That value was chosen so that the caesium second equalled, to the limit of human measuring ability in 1960 when it was adopted, the existing standard ephemeris second based on the Earth's orbit around the Sun. Because no other measurement involving time had been as precise, the effect of the change was less than the experimental uncertainty of all existing measurements.
Video Caesium standard
Technical details
The official definition of the second given by the BIMP at the 13th General Conference on Weights and Measures in 1967 is: ``The second is the duration of 9 192 631 770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium 133 atom.'' At its 1997 meeting the BIMP added to the previous definition the following specification: ``This definition refers to a caesium atom at rest at a temperature of 0 K.''
The meaning of the preceding definition is as follows. The caesium atom has a ground state electron state with configuration [Xe] 6s1 and, consequently, atomic term symbol 2S1/2. This means that there is one unpaired electron and the total electron spin of the atom is 1/2. Moreover, the nucleus of caesium-133 has a nuclear spin equal to 7/2. The simultaneous presence of electron spin and nuclear spin leads, by a mechanism called hyperfine interaction, to a (small) splitting of all energy levels into two sub-levels. One of the sub-levels corresponds to the electron and nuclear spin being parallel (i.e., pointing in the same direction), leading to a total spin F equal to F=7/2+1/2 =4; the other sub-level corresponds to anti-parallel electron and nuclear spin (i.e., pointing in opposite directions), leading to a total spin F=7/2-1/2=3. In the caesium atom it so happens that the sub-level lowest in energy is the one with F=3, while the F=4 sub-level lies energetically slightly above. When the atom is irradiated with electromagnetic radiation having an energy corresponding to the energetic difference between the two sub-levels the radiation is absorbed and the atom is excited, going from the F=3 sub-level to the F=4 one. After a small fraction of a second the atom will re-emit the radiation and return to its F=3 ground state. From the definition of the second it follows that the radiation in question has a frequency of exactly 9.19263177 GHz, corresponding to a wavelength of about 3.26 cm and therefore belonging to the microwave range.
Maps Caesium standard
See also
- Atomic clock
- Rubidium standard
References
- This article incorporates public domain material from the General Services Administration document "Federal Standard 1037C" (in support of MIL-STD-188).
External links
Source of the article : Wikipedia